{"id":1028,"date":"2020-10-10T11:25:08","date_gmt":"2020-10-10T03:25:08","guid":{"rendered":"http:\/\/qhdrz.com\/?p=1028"},"modified":"2020-11-23T14:27:43","modified_gmt":"2020-11-23T06:27:43","slug":"%e7%8e%bb%e7%92%83%e5%87%ba%e5%8f%a3%e7%be%8e%e5%9b%bd%e8%a1%8c%e4%b8%9a%e8%ae%a4%e8%af%81","status":"publish","type":"post","link":"https:\/\/qhdrz.com\/?p=1028","title":{"rendered":"\u73bb\u7483\u51fa\u53e3\u7f8e\u56fd\u4ea7\u54c1\u8ba4\u8bc1"},"content":{"rendered":"\n<h2>\u73bb\u7483\u51fa\u53e3\u7f8e\u56fd\u884c\u4e1a\u8ba4\u8bc1<\/h2>\n\n\n\n<h2>\u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483 &#8211; DOT\u6c7d\u8f66\u5b89\u5168\u73bb\u7483\u4ea7\u54c1\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u6c7d\u8f66\u5de5\u4e1a\u8bbe\u5907\u8ba4\u8bc1\u673a\u6784AMECA\uff08Automotive Manufacturers Equipment Compliance Agency, Inc\uff09<\/li><li>ANSI\/SAE Z26.1\uff1aSafety Glazing Materials for Glazing Motor Vehicles and Motor Vehicle Equipment Operating on Land Highways \uff08\u7f8e\u56fd\u56fd\u5bb6\u6807\u51c6\/\u7f8e\u56fd\u6c7d\u8f66\u5de5\u7a0b\u5e08\u534f\u4f1a\u6807\u51c6\uff1a\u9ad8\u901f\u516c\u8def\u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483\u6750\u6599\uff09<\/li><\/ul>\n\n\n\n<h2>\u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483 &#8211; UL \u94c1\u8def\u8f66\u8f86\u7528\u73bb\u7483\u8ba4\u8bc1\uff08FRA TYPE \uff09<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u8054\u90a6\u94c1\u8def\u5c40<\/li><li>\u6807\u51c6223\u6b3e\u8fdb\u884c\u8ba4\u8bc1\uff08Federal Railroad Administration, Part 223, Safety Glazing Standards, Locomotive, Passenger Cars and Cabooses\uff09\u3002<\/li><\/ul>\n\n\n\n<h2>\u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483 &#8211; UL\u673a\u573a\u822a\u7ad9\u697c\u7528\u73bb\u7483\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>National Fire Protection Association Standard for Fire Doors and Windows, NFPA 415\uff1aStandard on Airport Terminal Buildings, Fuel Ramp Drainage and Loading Walkways\uff08\u7f8e\u56fd\u6d88\u9632\u534f\u4f1a\u6807\u51c6NFPA 415\uff1a\u673a\u573a\u822a\u7ad9\u697c\u3001\u52a0\u6cb9\u7ad9\u548c\u8dd1\u9053\u95e8\u7a97\u9632\u706b\u6807\u51c6\uff09<\/li><\/ul>\n\n\n\n<h2>\u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483 &#8211; NMMA\u8239\u7528\u5b89\u5168\u73bb\u7483<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u8239\u8236\u5de5\u4e1a\u534f\u4f1a\uff08National Marine Manufacturers Association\uff0cNMMA\uff09\u5bf9\u8239\u7528\u73bb\u7483\u6750\u6599\u8fdb\u884c\u8ba4\u8bc1\uff0c\u6309\u7167NMMA H-13-87 Reaffirmed 4\/94 \u6807\u51c6\u8fdb\u884c\u8ba4\u8bc1\uff0c2005\u5e74\u5f00\u59cb\u91c7\u7528NMMA H-3\u6807\u51c6\u8fdb\u884c\u68c0\u6d4b\u8ba4\u8bc1\u3002<\/li><\/ul>\n\n\n\n<h2>\u5efa\u7b51\u5b89\u5168\u73bb\u7483SGCC\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u5b89\u5168\u73bb\u7483\u8ba4\u8bc1\u59d4\u5458\u4f1a\uff08SGCC\uff0cSafety Glazing Certification Council)<\/li><li>ANSI Z97.1-1984\uff1aAmerican National Standard for Safety Glazing Materials used in Buildings \u2013 Safety Performance Specifications and Methods of Test\uff08\u7f8e\u56fd\u56fd\u5bb6\u6807\u51c6\u5efa\u7b51\u5b89\u5168\u73bb\u7483\u5b89\u5168\u6027\u80fd\u4e0e\u6d4b\u8bd5\u65b9\u6cd5\uff09<\/li><li>CPSC 16 CFR 1201: Consumer Product Safety Commission Safety Standard for Architectural Glazing Materials \u2013 codified at Title 16, Part 1201 of the Code of Federal Regulations(\u6d88\u8d39\u4ea7\u54c1\u5b89\u5168\u59d4\u5458\u4f1a\u6807\u51c6\uff0c\u5efa\u7b51\u5b89\u5168\u73bb\u7483\u6750\u6599\u7f8e\u56fd\u8054\u90a6\u6cd5\u89c41201\u6761\u7b2c16\u6b3e)<\/li><\/ul>\n\n\n\n<h2>\u5efa\u7b51\u5b89\u5168\u73bb\u7483 UL\u8ba4\u8bc1 (Underwriters Laboratories)<\/h2>\n\n\n\n<ul><li>\u9632\u706b\u73bb\u7483\u8ba4\u8bc1 UL 263\uff1aFire Tests of Building Construction and Materials\uff08\u5efa\u7b51\u53ca\u6750\u6599\u9632\u706b\u6d4b\u8bd5\u6807\u51c6\uff09<\/li><li>\u9632\u5f39\u73bb\u7483\u8ba4\u8bc1\uff1aUL 752\uff1aBullet Resisting Equipment\uff08\u9632\u5f39\u8bbe\u5907\u6807\u51c6\uff09\uff0c\u9632\u5f39\u7b49\u7ea7\u5206\u4e3a8\u3002<\/li><li>UL\u9632\u76d7\u73bb\u7483\u8ba4\u8bc1\uff1aUL 972:Burglary Resisting Glazing Material(\u9632\u76d7\u73bb\u7483\u6807\u51c6)\u3002<\/li><li>UL\u73bb\u7483\u7816\u9632\u706b\u8ba4\u8bc1\uff1aANSI\/UL 9\uff1aFire Tests of Window Assemblies\uff08\u7f8e\u56fd\u56fd\u5bb6\u6807\u51c6\/UL\u6807\u51c6\uff1a\u7a97\u6784\u4ef6\u653e\u706b\u6d4b\u8bd5\uff09\/ ANSI\/NFPA 257 \uff1aStandard on Fire Test for Window and Glass Block Assemblies\uff08\u7f8e\u56fd\u56fd\u5bb6\u6807\u51c6\/\u7f8e\u56fd\u6d88\u9632\u534f\u4f1a\u6807\u51c6\uff1a\u7a97\u548c\u73bb\u7483\u7816\u5efa\u7b51\u9632\u706b\u6d4b\u8bd5\uff09\/ Uniform Building Code Standard UBC 7-4 \uff1aFire Tests of Window Assemblies\uff08\u7edf\u4e00\u5efa\u7b51\u6cd5\u89c4\u6807\u51c6:\u7a97\u7684\u9632\u706b\u6d4b\u8bd5\uff09<\/li><\/ul>\n\n\n\n<h2>\u6d3b\u52a8\u4f4f\u623f\u7528\u7a97\u548c\u6ed1\u52a8\u73bb\u7483\u95e8\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u4f4f\u623f\u53ca\u57ce\u5e02\u53d1\u5c55\u90e8\u6d3b\u52a8\u4f4f\u623f\u5efa\u7b51\u548c\u5b89\u5168\u6807\u51c6\uff08Department of Housing and Urban Development Mobile Home Construction and Safety Standards, Section 280.403, Chapter II of 24CFR, December 18, 1975\u548cDepartment of Housing and Urban Development Mobile Home Construction and Safety Standards, Sections 280.403 and 280.404, Chapter II of 24CFR, December 18, 1975<\/li><\/ul>\n\n\n\n<h2>\u4e2d\u7a7a\u73bb\u7483\u8ba4\u8bc1 &#8211; IGMA\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u5317\u7f8e\u4e2d\u7a7a\u73bb\u7483\u5de5\u4e1a\u8054\u5408\u4f1a<\/li><li>\u5317\u7f8e\u8ba4\u8bc1 :\u7f8e\u56fdASTM E 2190\uff1a Standard Specification for Insulating Glass Unit Performance and Evaluation\uff08\u4e2d\u7a7a\u73bb\u7483\u6027\u80fd\u548c\u8bc4\u4ef7\u6807\u51c6\uff09\u3002<\/li><li>\u52a0\u62ff\u5927\u8ba4\u8bc1\uff1aCGSB12.8<\/li><li>\u7f8e\u56fdASTM\u8ba4\u8bc1\uff1aSTM E 774 \/ \u7f8e\u56fd\u8054\u5408\u5b9e\u9a8c\u5ba4ALI \/ \u7f8e\u56fd\u4e2d\u7a7a\u73bb\u7483\u8ba4\u8bc1\u59d4\u5458\u4f1aIGCC \/ \u7f8e\u56fd\u5168\u56fd\u8ba4\u53ef\u4e0e\u7ba1\u7406\u534f\u4f1aNAMI<\/li><\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2>IGCC\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u4e2d\u7a7a\u73bb\u7483\u8ba4\u8bc1\u59d4\u5458\u4f1a\uff08IGCC\uff09<\/li><li>ASTM E 773\uff1aAccelerated Weathering of Sealed Insulating Glass Units\uff08\u4e2d\u7a7a\u73bb\u7483\u8001\u5316\u8bd5\u9a8c\u65b9\u6cd5\uff09<\/li><li>E 774\uff1a Classification of the Durability of Sealed Insulating Glass Units\uff08\u4e2d\u7a7a\u73bb\u7483\u8010\u4e45\u6027\u5206\u7c7b\uff09<\/li><li>ASTM E2190\uff1a Standard Specification for Insulating Glass Unit Performance and Evaluation\uff08\u4e2d\u7a7a\u73bb\u7483\u6027\u80fd\u548c\u8bc4\u4ef7\u6807\u51c6\uff09<\/li><\/ul>\n\n\n\n<h2>NAMI\u8ba4\u8bc1<\/h2>\n\n\n\n<p>\u7f8e\u56fd\u5168\u56fd\u8ba4\u53ef\u4e0e\u7ba1\u7406\u5b66\u4f1a\uff08National Accreditation and Management Institute, Inc.\uff0cNAMI\uff09<\/p>\n\n\n\n<ul><li>ASTM E773\uff0cASTM E774\uff0cE1887\uff1aStandard Test Method for Fog Determination(\u4e2d\u7a7a\u73bb\u7483\u7ed3\u9732\u6d4b\u8bd5\u65b9\u6cd5)\uff1b<\/li><\/ul>\n\n\n\n<p>\u9488\u5bf9\u5317\u7f8e\u5e02\u573a\uff08HIGS\uff09<\/p>\n\n\n\n<ul><li>ASTM E2188: Standard Test Method for Insulating Glass Performance\uff08\u4e2d\u7a7a\u73bb\u7483\u6027\u80fd\u6d4b\u8bd5\uff09<\/li><li>ASTM E2189: Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units\uff08\u4e2d\u7a7a\u73bb\u7483\u9632\u7ed3\u9732\u6d4b\u8bd5\uff09<\/li><li>ASTM E2190: Standard Specifications for Insulating Glass Unit Performance and Evaluation\uff08\u4e2d\u7a7a\u73bb\u7483\u6027\u80fd\u548c\u8bc4\u4ef7\u6807\u51c6\uff09\u3002<\/li><\/ul>\n\n\n\n<h2>ALI\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u8054\u5408\u5b9e\u9a8c\u5ba4<\/li><\/ul>\n\n\n\n<h2>\u5efa\u7b51\u7a97\u8ba4\u8bc1<\/h2>\n\n\n\n<ul><li>\u7f8e\u56fd\u5efa\u7b51\u95e8\u7a97\u5de5\u4e1a\u534f\u4f1a\uff08American Architectural Manufacturers Association<\/li><li>AAMA\u91d1\u8272\u6807\u7b7e\uff08GOLD LABEL\uff09\u8ba4\u8bc1<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>\u73bb\u7483\u51fa\u53e3\u7f8e\u56fd\u884c\u4e1a\u8ba4\u8bc1 \u4ea4\u901a\u5de5\u5177\u7528\u5b89\u5168\u73bb\u7483 &#8211; DOT\u6c7d\u8f66\u5b89\u5168\u73bb\u7483\u4ea7\u54c1\u8ba4\u8bc1 \u7f8e\u56fd\u6c7d\u8f66\u5de5\u4e1a\u8bbe\u5907\u8ba4\u8bc1\u673a\u6784AMECA\uff08Automotive Manufacturers Equipment Compliance Agency, Inc\uff09 ANSI\/SAE Z26.1\uff1aSafety Glazing Materials for Glazing Motor Vehicles and Motor Vehicle Equipment Operating on Land Highways \uff08\u7f8e\u56fd\u56fd\u5bb6\u6807\u51c6\/&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1092,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[5],"tags":[],"_links":{"self":[{"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/posts\/1028"}],"collection":[{"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qhdrz.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1028"}],"version-history":[{"count":3,"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/posts\/1028\/revisions"}],"predecessor-version":[{"id":1033,"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/posts\/1028\/revisions\/1033"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qhdrz.com\/index.php?rest_route=\/wp\/v2\/media\/1092"}],"wp:attachment":[{"href":"https:\/\/qhdrz.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1028"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/qhdrz.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1028"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/qhdrz.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1028"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}